<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>AXON Series Archives - Davicom Exchange Support Portal (DEX)</title>
	<atom:link href="https://dex.davicom.com/kbtopic/axon-series/feed/" rel="self" type="application/rss+xml" />
	<link>https://dex.davicom.com/kbtopic/axon-series/</link>
	<description></description>
	<lastBuildDate>Wed, 28 May 2025 17:54:01 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.5</generator>
	<item>
		<title>AXON Connections and Switch Configurations</title>
		<link>https://dex.davicom.com/kb/axon-connections-and-switch-configurations/</link>
					<comments>https://dex.davicom.com/kb/axon-connections-and-switch-configurations/#respond</comments>
		
		<dc:creator><![CDATA[Julia Ahern]]></dc:creator>
		<pubDate>Fri, 26 Jul 2024 18:07:01 +0000</pubDate>
				<guid isPermaLink="false">https://dex.davicom.com/?post_type=kb&#038;p=6431</guid>

					<description><![CDATA[<p>The AXON can run on any DC voltage between 5 and 30 Vdc. The current consumption depends on the actual supply voltage, but is typically 110<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://dex.davicom.com/kb/axon-connections-and-switch-configurations/">AXON Connections and Switch Configurations</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img fetchpriority="high" decoding="async" width="725" height="176" src="https://dex.davicom.com/wp-content/uploads/2024/07/image007-1.png" alt="" class="wp-image-6370" style="width:494px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image007-1.png 725w, https://dex.davicom.com/wp-content/uploads/2024/07/image007-1-300x73.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/image007-1-260x63.png 260w, https://dex.davicom.com/wp-content/uploads/2024/07/image007-1-50x12.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/image007-1-150x36.png 150w, https://dex.davicom.com/wp-content/uploads/2024/07/image007-1-380x92.png 380w, https://dex.davicom.com/wp-content/uploads/2024/07/image007-1-600x146.png 600w" sizes="(max-width:767px) 480px, 725px" /></figure></div><p>The AXON can run on any DC voltage between 5 and 30 Vdc. The current consumption depends on the actual supply voltage, but is typically 110 mA at 12 Vdc for the 8A &amp; 8D and up to 190 mA for the 5R (with all relays energized). A 2.1mm locking DC Power barrel connector with negative shell is used.&nbsp;</p><p>Connect the power supply to your power mains and then connect the 2.1mm locking barrel connector to the AXON.</p><p>Once power is applied to the AXON, the unit takes about 5 to 10 seconds to boot-up (except on first start-up or following a factory reset), see <a href="https://dex.davicom.com/kb/initial-log-in-and-network-setup-axon-neuro-series/">this article</a>. The unit is ready once the “ACTIVITY” heartbeat light starts blinking. </p><p>Depending on the type of AXON that you are using, you will need to properly set the DIP switches found on the side of the unit.&nbsp;</p><h2 class="wp-block-heading">AXON-8A Connections and Switch Settings</h2><p>The AXON-8A&#8217;s flexible analog inputs can accept a wide range of signals. Sensors with various voltage outputs (±0.5, ±2.5, ±5, ±10, ±20 and -40 or +40 V) or current outputs (4-20mA), be they bipolar or differential, can all be connected to the AXON’s inputs. Single-ended measurements are also possible.</p><figure class="wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex"><figure class="wp-block-image size-large"><img decoding="async" width="540" height="720" data-id="6441" src="https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-edited.jpg" alt="" class="wp-image-6441" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-edited.jpg 540w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-edited-225x300.jpg 225w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-edited-110x146.jpg 110w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-edited-38x50.jpg 38w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-edited-56x75.jpg 56w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-edited-195x260.jpg 195w" sizes="(max-width:767px) 480px, 540px" /></figure>

<figure class="wp-block-image size-large"><img decoding="async" width="1024" height="576" data-id="6439" src="https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1024x576.jpg" alt="" class="wp-image-6439" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1024x576.jpg 1024w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-300x169.jpg 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-768x432.jpg 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-260x146.jpg 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-50x28.jpg 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-133x75.jpg 133w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-380x214.jpg 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1200x675.jpg 1200w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-600x338.jpg 600w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2.jpg 1280w" sizes="(max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure>

<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="576" data-id="6440" src="https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1024x576.jpg" alt="" class="wp-image-6440" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1024x576.jpg 1024w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-300x169.jpg 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-768x432.jpg 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-260x146.jpg 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-50x28.jpg 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-133x75.jpg 133w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-380x214.jpg 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1200x675.jpg 1200w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-600x338.jpg 600w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3.jpg 1280w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure></figure><p>DIP switches are used to select whether the input (on an individual basis) operates in bipolar/differential mode (switch up) or in 4-20 mA mode (switch down).&nbsp;</p><p>The other set of switches is used to connect the (-) terminal of an individual input to ground if balanced/differential mode is not required (single-ended signals). If using 4-20 mA mode, ensure the corresponding (-) TO GND switch is up.&nbsp;</p><h2 class="wp-block-heading">AXON-8D Connections and Switch Settings</h2><p>The AXON-8D’s inputs are designed for reading logic levels or wet/dry relay contacts, with programmable active-high or active-low settings.</p><figure class="wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-2 is-layout-flex wp-block-gallery-is-layout-flex"><figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="540" height="720" data-id="6445" src="https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-1-edited.jpg" alt="" class="wp-image-6445" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-1-edited.jpg 540w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-1-edited-225x300.jpg 225w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-1-edited-110x146.jpg 110w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-1-edited-38x50.jpg 38w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-1-edited-56x75.jpg 56w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-1-edited-195x260.jpg 195w" sizes="auto, (max-width:767px) 480px, 540px" /></figure>

<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="576" data-id="6443" src="https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1-1024x576.jpg" alt="" class="wp-image-6443" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1-1024x576.jpg 1024w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1-300x169.jpg 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1-768x432.jpg 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1-260x146.jpg 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1-50x28.jpg 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1-133x75.jpg 133w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1-380x214.jpg 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1-1200x675.jpg 1200w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1-600x338.jpg 600w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-1.jpg 1280w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure>

<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="576" data-id="6444" src="https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1-1024x576.jpg" alt="" class="wp-image-6444" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1-1024x576.jpg 1024w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1-300x169.jpg 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1-768x432.jpg 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1-260x146.jpg 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1-50x28.jpg 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1-133x75.jpg 133w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1-380x214.jpg 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1-1200x675.jpg 1200w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1-600x338.jpg 600w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-1.jpg 1280w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure></figure><p>DIP switches are used to determine whether each input’s return signal is connected to the unit’s common ground, or not (ISOLATED). The other set of switches determines whether each individual input will have a pull-up resistor (10kΩ to internal +3.3V, diode protected against reverse or over-voltage) or not.</p><h2 class="wp-block-heading">AXON-5R Connections</h2><p>The AXON-5R’s relay outputs can control other devices. From remotely switching off a faulty device to automatically power-cycling network elements, the AXON-5R can take smart decisions to keep your operations humming along. The AXON 5R does not have any configuration switches.</p><figure class="wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-3 is-layout-flex wp-block-gallery-is-layout-flex"><figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="540" height="720" data-id="6449" src="https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-2-edited.jpg" alt="" class="wp-image-6449" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-2-edited.jpg 540w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-2-edited-225x300.jpg 225w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-2-edited-110x146.jpg 110w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-2-edited-38x50.jpg 38w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-2-edited-56x75.jpg 56w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide1-2-edited-195x260.jpg 195w" sizes="auto, (max-width:767px) 480px, 540px" /></figure>

<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="576" data-id="6447" src="https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2-1024x576.jpg" alt="" class="wp-image-6447" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2-1024x576.jpg 1024w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2-300x169.jpg 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2-768x432.jpg 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2-260x146.jpg 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2-50x28.jpg 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2-133x75.jpg 133w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2-380x214.jpg 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2-1200x675.jpg 1200w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2-600x338.jpg 600w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide2-2.jpg 1280w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure>

<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="1024" height="576" data-id="6448" src="https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2-1024x576.jpg" alt="" class="wp-image-6448" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2-1024x576.jpg 1024w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2-300x169.jpg 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2-768x432.jpg 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2-260x146.jpg 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2-50x28.jpg 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2-133x75.jpg 133w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2-380x214.jpg 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2-1200x675.jpg 1200w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2-600x338.jpg 600w, https://dex.davicom.com/wp-content/uploads/2024/07/Slide3-2.jpg 1280w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure></figure><p>The post <a href="https://dex.davicom.com/kb/axon-connections-and-switch-configurations/">AXON Connections and Switch Configurations</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dex.davicom.com/kb/axon-connections-and-switch-configurations/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Axon Series Quick Start Guide</title>
		<link>https://dex.davicom.com/kb/axon-series-quick-start-guide-pdf/</link>
					<comments>https://dex.davicom.com/kb/axon-series-quick-start-guide-pdf/#respond</comments>
		
		<dc:creator><![CDATA[Julia Ahern]]></dc:creator>
		<pubDate>Fri, 24 Nov 2023 13:23:36 +0000</pubDate>
				<guid isPermaLink="false">https://dex.davicom.com/?post_type=kb&#038;p=5919</guid>

					<description><![CDATA[<p>Head over to the Manuals &#38; Guides page to view the Axon Series Quick Start Guide.</p>
<p>The post <a href="https://dex.davicom.com/kb/axon-series-quick-start-guide-pdf/">Axon Series Quick Start Guide</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Head over to the Manuals &amp; Guides page to view the Axon Series Quick Start Guide.</p><p></p><div
			
			class="so-widget-sow-button so-widget-sow-button-flat-d5eeaf4fc640"
			
		><div class="ow-button-base ow-button-align-center">
			<a
					href="https://dex.davicom.com/documents-downloads/manuals-guides/"
					class="sowb-button ow-icon-placement-left ow-button-hover" target="_blank" rel="noopener noreferrer" 	>
		<span>
			
			Go to Manuals &amp; Guides		</span>
			</a>
	</div>
</div><p>The post <a href="https://dex.davicom.com/kb/axon-series-quick-start-guide-pdf/">Axon Series Quick Start Guide</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dex.davicom.com/kb/axon-series-quick-start-guide-pdf/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Axon Series SNMP MIB</title>
		<link>https://dex.davicom.com/kb/axon-series-snmp-mib/</link>
					<comments>https://dex.davicom.com/kb/axon-series-snmp-mib/#respond</comments>
		
		<dc:creator><![CDATA[Julia Ahern]]></dc:creator>
		<pubDate>Fri, 24 Nov 2023 14:17:32 +0000</pubDate>
				<guid isPermaLink="false">https://dex.davicom.com/?post_type=kb&#038;p=5923</guid>

					<description><![CDATA[<p>Go to the Software &#38; Firmware page to access the Axon Series SNMP MIB. Please note that you must be logged in to view the page.</p>
<p>The post <a href="https://dex.davicom.com/kb/axon-series-snmp-mib/">Axon Series SNMP MIB</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Go to the <a href="https://dex.davicom.com/documents-downloads/software-firmware/">Software &amp; Firmware</a> page to access the Axon Series SNMP MIB. Please note that you must be logged in to view the page.</p><p>The post <a href="https://dex.davicom.com/kb/axon-series-snmp-mib/">Axon Series SNMP MIB</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dex.davicom.com/kb/axon-series-snmp-mib/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>AXON/NEURO as a Modbus Unit</title>
		<link>https://dex.davicom.com/kb/axon-neuro-as-a-modbus-unit/</link>
					<comments>https://dex.davicom.com/kb/axon-neuro-as-a-modbus-unit/#respond</comments>
		
		<dc:creator><![CDATA[Julia Ahern]]></dc:creator>
		<pubDate>Mon, 29 Jul 2024 13:36:41 +0000</pubDate>
				<guid isPermaLink="false">https://dex.davicom.com/?post_type=kb&#038;p=6497</guid>

					<description><![CDATA[<p>AXON/NEURO units can be used to provide simple I/O expansion for Davicom&#8217;s Cortex units, or for any other MODBUS master device. In MODBUS Mode, the hamburger<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://dex.davicom.com/kb/axon-neuro-as-a-modbus-unit/">AXON/NEURO as a Modbus Unit</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>AXON/NEURO units can be used to provide simple I/O expansion for Davicom&#8217;s Cortex units, or for any other MODBUS master device. In MODBUS Mode, the hamburger menu is as shown below: Most System settings are the same as for Standalone Mode, except that the Home / IP Parameters section will be different. The SNMP tab is replaced by the Modbus TCP tab and there are no Email or Axon/Neuro Command server tabs.</p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="202" height="324" src="https://dex.davicom.com/wp-content/uploads/2024/07/image063.png" alt="" class="wp-image-6426" style="width:161px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image063.png 202w, https://dex.davicom.com/wp-content/uploads/2024/07/image063-187x300.png 187w, https://dex.davicom.com/wp-content/uploads/2024/07/image063-91x146.png 91w, https://dex.davicom.com/wp-content/uploads/2024/07/image063-31x50.png 31w, https://dex.davicom.com/wp-content/uploads/2024/07/image063-47x75.png 47w, https://dex.davicom.com/wp-content/uploads/2024/07/image063-162x260.png 162w" sizes="auto, (max-width:767px) 202px, 202px" /></figure></div><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="757" height="621" src="https://dex.davicom.com/wp-content/uploads/2024/07/image064.png" alt="" class="wp-image-6427" style="width:596px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image064.png 757w, https://dex.davicom.com/wp-content/uploads/2024/07/image064-300x246.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/image064-178x146.png 178w, https://dex.davicom.com/wp-content/uploads/2024/07/image064-50x41.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/image064-91x75.png 91w, https://dex.davicom.com/wp-content/uploads/2024/07/image064-317x260.png 317w, https://dex.davicom.com/wp-content/uploads/2024/07/image064-600x492.png 600w" sizes="auto, (max-width:767px) 480px, 757px" /></figure></div><p>When a new, non-configured AXON/NEURO is connected to the same network as a Davicom Cortex it will be detected automatically and added as a Modbus expansion unit. Similar to adding a MEXM expansion device to the Davicom Cortex, users may also click the <strong>Detect</strong> button in the Davicom Cortex menu under <strong>Devices</strong> > <strong>AXON &amp; NEURO.</strong> Make sure the IP address of the AXON or NEURO is visible to the Davicom Cortex so that it can detect it.</p><div class="wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-1 wp-block-group-is-layout-flex"><figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="284" height="531" src="https://dex.davicom.com/wp-content/uploads/2024/07/Devices-menu.png" alt="" class="wp-image-6741" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Devices-menu.png 284w, https://dex.davicom.com/wp-content/uploads/2024/07/Devices-menu-160x300.png 160w, https://dex.davicom.com/wp-content/uploads/2024/07/Devices-menu-78x146.png 78w, https://dex.davicom.com/wp-content/uploads/2024/07/Devices-menu-27x50.png 27w, https://dex.davicom.com/wp-content/uploads/2024/07/Devices-menu-40x75.png 40w, https://dex.davicom.com/wp-content/uploads/2024/07/Devices-menu-139x260.png 139w" sizes="auto, (max-width:767px) 284px, 284px" /></figure>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="803" height="203" src="https://dex.davicom.com/wp-content/uploads/2024/07/detect.png" alt="" class="wp-image-6740" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/detect.png 803w, https://dex.davicom.com/wp-content/uploads/2024/07/detect-300x76.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/detect-768x194.png 768w, https://dex.davicom.com/wp-content/uploads/2024/07/detect-260x66.png 260w, https://dex.davicom.com/wp-content/uploads/2024/07/detect-50x13.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/detect-150x38.png 150w, https://dex.davicom.com/wp-content/uploads/2024/07/detect-380x96.png 380w, https://dex.davicom.com/wp-content/uploads/2024/07/detect-600x152.png 600w" sizes="auto, (max-width:767px) 480px, (max-width:803px) 100vw, 803px" /></figure></div><p>More details on this mode of operation will be provided soon.</p><p>The tables below show the different MODBUS register addresses for the 3 types of AXON units.</p><figure class="wp-block-table"><table><tbody><tr><td><strong>AXON-8A</strong></td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td><strong><em>Address</em></strong></td><td><strong><em>Description</em></strong></td><td><strong><em>Attribute</em></strong></td></tr><tr><td>30001</td><td>Analog input #1 (0-4095 : Offset binary)</td><td>Read</td></tr><tr><td>30002</td><td>Analog input #2 (0-4095 : Offset binary)</td><td>Read</td></tr><tr><td>30003</td><td>Analog input #3 (0-4095 : Offset binary)</td><td>Read</td></tr><tr><td>30004</td><td>Analog input #4 (0-4095 : Offset binary)</td><td>Read</td></tr><tr><td>30005</td><td>Analog input #5 (0-4095 : Offset binary)</td><td>Read</td></tr><tr><td>30006</td><td>Analog input #6 (0-4095 : Offset binary)</td><td>Read</td></tr><tr><td>30007</td><td>Analog input #7 (0-4095 : Offset binary)</td><td>Read</td></tr><tr><td>30008</td><td>Analog input #8 (0-4095 : Offset binary)</td><td>Read</td></tr><tr><td>&nbsp;</td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td>31001-31002</td><td>Analog input #1 (Float)</td><td>Read</td></tr><tr><td>31003-31004</td><td>Analog input #2 (Float)</td><td>Read</td></tr><tr><td>31005-31006</td><td>Analog input #3 (Float)</td><td>Read</td></tr><tr><td>31007-31008</td><td>Analog input #4 (Float)</td><td>Read</td></tr><tr><td>31009-31010</td><td>Analog input #5 (Float)</td><td>Read</td></tr><tr><td>31011-31012</td><td>Analog input #6 (Float)</td><td>Read</td></tr><tr><td>31013-31014</td><td>Analog input #7 (Float)</td><td>Read</td></tr><tr><td>31015-31016</td><td>Analog input #8 (Float)</td><td>Read</td></tr><tr><td>&nbsp;</td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td>40001</td><td>Analog input #1 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40002</td><td>Analog input #2 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40003</td><td>Analog input #3 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40004</td><td>Analog input #4 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40005</td><td>Analog input #5 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40006</td><td>Analog input #6 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40007</td><td>Analog input #7 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40008</td><td>Analog input #8 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>&nbsp;</td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td>42001</td><td>IP Address &#8211; Most significant (HEX)</td><td>Read/Write</td></tr><tr><td>42002</td><td>IP Address &#8211; Least significant (HEX)</td><td>Read/Write</td></tr><tr><td>42003</td><td>Netmask &#8211; Most significant (HEX)</td><td>Read/Write</td></tr><tr><td>42004</td><td>Netmask &#8211; Least significant (HEX)</td><td>Read/Write</td></tr><tr><td>42005</td><td>Reserved</td><td>Read/Write</td></tr><tr><td>42006</td><td>Modbus TCP port</td><td>Read/Write</td></tr><tr><td>42007</td><td>Modbus Unit ID</td><td>Read/Write</td></tr><tr><td>42008</td><td>Apply changes (write 1 to apply changes)</td><td>Read/Write</td></tr></tbody></table></figure><figure class="wp-block-table"><table><tbody><tr><td><strong>AXON-8D</strong></td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td><strong><em>Address</em></strong></td><td><strong><em>Description</em></strong></td><td><strong><em>Attribute</em></strong></td></tr><tr><td>10001</td><td>Digital input #1 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10002</td><td>Digital input #2 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10003</td><td>Digital input #3 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10004</td><td>Digital input #4 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10005</td><td>Digital input #5 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10006</td><td>Digital input #6 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10007</td><td>Digital input #7 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10008</td><td>Digital input #8 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>&nbsp;</td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td>42001</td><td>IP Address &#8211; Most significant (HEX)</td><td>Read/Write</td></tr><tr><td>42002</td><td>IP Address &#8211; Least significant (HEX)</td><td>Read/Write</td></tr><tr><td>42003</td><td>Netmask &#8211; Most significant (HEX)</td><td>Read/Write</td></tr><tr><td>42004</td><td>Netmask &#8211; Least significant (HEX)</td><td>Read/Write</td></tr><tr><td>42005</td><td>Reserved</td><td>Read/Write</td></tr><tr><td>42006</td><td>Modbus TCP port</td><td>Read/Write</td></tr><tr><td>42007</td><td>Modbus Unit ID</td><td>Read/Write</td></tr><tr><td>42008</td><td>Apply changes (write 1 to apply changes)</td><td>Read/Write</td></tr></tbody></table></figure><figure class="wp-block-table"><table><tbody><tr><td><strong>AXON-5R</strong></td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td><strong><em>Address</em></strong></td><td><strong><em>Description</em></strong></td><td><strong><em>Attribute</em></strong></td></tr><tr><td>00001</td><td>Relay #1 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00002</td><td>Relay #2 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00003</td><td>Relay #3 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00004</td><td>Relay #4 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00005</td><td>Relay #5 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>&nbsp;</td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td>42001</td><td>IP Address &#8211; Most significant (HEX)</td><td>Read/Write</td></tr><tr><td>42002</td><td>IP Address – Least significant (HEX)</td><td>Read/Write</td></tr><tr><td>42003</td><td>Netmask &#8211; Most significant (HEX)</td><td>Read/Write</td></tr><tr><td>42004</td><td>Netmask &#8211; Least significant (HEX)</td><td>Read/Write</td></tr><tr><td>42005</td><td>Reserved</td><td>Read/Write</td></tr><tr><td>42006</td><td>Modbus TCP port</td><td>Read/Write</td></tr><tr><td>42007</td><td>Modbus Unit ID</td><td>Read/Write</td></tr><tr><td>42008</td><td>Apply changes (write 1 to apply changes)</td><td>Read/Write</td></tr></tbody></table></figure><p>The tables below show the MODBUS registers for NEURO units.</p><figure class="wp-block-table"><table><tbody><tr><td colspan="2"><strong>MODBUS REGISTERS</strong></td><td></td></tr><tr><td><strong><em>NEURO</em></strong></td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td><strong><em>Address</em></strong></td><td><strong><em>Description</em></strong></td><td><strong><em>Attribute</em></strong></td></tr><tr><td>42001</td><td>IP Address &#8211; Most significant (HEX)</td><td>Read/Write</td></tr><tr><td>42002</td><td>IP Address &#8211; Least significant (HEX)</td><td>Read/Write</td></tr><tr><td>42003</td><td>Netmask &#8211; Most significant (HEX)</td><td>Read/Write</td></tr><tr><td>42004</td><td>Netmask &#8211; Least significant (HEX)</td><td>Read/Write</td></tr><tr><td>42005</td><td>Reserved</td><td>Read/Write</td></tr><tr><td>42006</td><td>Modbus TCP port</td><td>Read/Write</td></tr><tr><td>42007</td><td>Modbus Unit ID</td><td>Read/Write</td></tr><tr><td>42008</td><td>Apply changes (write 1 to apply changes)</td><td>Read/Write</td></tr><tr><td></td><td></td><td></td></tr><tr><td><strong><em>NEURO ANALOG INPUTS</em></strong></td><td><strong><em>&nbsp;</em></strong></td><td><strong><em>&nbsp;</em></strong></td></tr><tr><td><strong><em>Address</em></strong></td><td><strong><em>Description</em></strong></td><td><strong><em>Attribute</em></strong></td></tr><tr><td>30001</td><td>Analog input #1 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30002</td><td>Analog input #2 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30003</td><td>Analog input #3 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30004</td><td>Analog input #4 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30005</td><td>Analog input #5 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30006</td><td>Analog input #6 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30007</td><td>Analog input #7 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30008</td><td>Analog input #8 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30009</td><td>Analog input #9 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30010</td><td>Analog input #10 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30011</td><td>Analog input #11 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30012</td><td>Analog input #12 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30013</td><td>Analog input #13 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30014</td><td>Analog input #14 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30015</td><td>Analog input #15 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30016</td><td>Analog input #16 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30017</td><td>Analog input #17 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30018</td><td>Analog input #18 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30019</td><td>Analog input #19 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30020</td><td>Analog input #20 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30021</td><td>Analog input #21 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30022</td><td>Analog input #22 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30023</td><td>Analog input #23 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30024</td><td>Analog input #24 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30025</td><td>Analog input #25 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30026</td><td>Analog input #26 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30027</td><td>Analog input #27 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30028</td><td>Analog input #28 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30029</td><td>Analog input #29 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30030</td><td>Analog input #30 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30031</td><td>Analog input #31 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30032</td><td>Analog input #32 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30033</td><td>Analog input #33 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30034</td><td>Analog input #34 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30035</td><td>Analog input #35 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30036</td><td>Analog input #36 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30037</td><td>Analog input #37 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30038</td><td>Analog input #38 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30039</td><td>Analog input #39 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td>30040</td><td>Analog input #40 (0-4095:Offset binary)</td><td>Read</td></tr><tr><td><strong><em>Address</em></strong></td><td><strong><em>Description</em></strong></td><td><strong><em>Attribute</em></strong></td></tr><tr><td>31001-31002</td><td>Analog input #1 (Float)</td><td>Read</td></tr><tr><td>31003-31004</td><td>Analog input #2 (Float)</td><td>Read</td></tr><tr><td>31005-31006</td><td>Analog input #3 (Float)</td><td>Read</td></tr><tr><td>31007-31008</td><td>Analog input #4 (Float)</td><td>Read</td></tr><tr><td>31009-31010</td><td>Analog input #5 (Float)</td><td>Read</td></tr><tr><td>31011-31012</td><td>Analog input #6 (Float)</td><td>Read</td></tr><tr><td>31013-31014</td><td>Analog input #7 (Float)</td><td>Read</td></tr><tr><td>31015-31016</td><td>Analog input #8 (Float)</td><td>Read</td></tr><tr><td>31017-31018</td><td>Analog input #9 (Float)</td><td>Read</td></tr><tr><td>31019-31020</td><td>Analog input #10 (Float)</td><td>Read</td></tr><tr><td>31021-31022</td><td>Analog input #11 (Float)</td><td>Read</td></tr><tr><td>31023-31024</td><td>Analog input #12 (Float)</td><td>Read</td></tr><tr><td>31025-31026</td><td>Analog input #13 (Float)</td><td>Read</td></tr><tr><td>31027-31028</td><td>Analog input #14 (Float)</td><td>Read</td></tr><tr><td>31029-31030</td><td>Analog input #15 (Float)</td><td>Read</td></tr><tr><td>31031-31032</td><td>Analog input #16 (Float)</td><td>Read</td></tr><tr><td>31033-31034</td><td>Analog input #17 (Float)</td><td>Read</td></tr><tr><td>31035-31036</td><td>Analog input #18 (Float)</td><td>Read</td></tr><tr><td>31037-31038</td><td>Analog input #19 (Float)</td><td>Read</td></tr><tr><td>31039-31040</td><td>Analog input #20 (Float)</td><td>Read</td></tr><tr><td>31041-31042</td><td>Analog input #21 (Float)</td><td>Read</td></tr><tr><td>31043-31044</td><td>Analog input #22 (Float)</td><td>Read</td></tr><tr><td>31045-31046</td><td>Analog input #23 (Float)</td><td>Read</td></tr><tr><td>31047-31048</td><td>Analog input #24 (Float)</td><td>Read</td></tr><tr><td>31049-31050</td><td>Analog input #25 (Float)</td><td>Read</td></tr><tr><td>31051-31052</td><td>Analog input #26 (Float)</td><td>Read</td></tr><tr><td>31053-31054</td><td>Analog input #27 (Float)</td><td>Read</td></tr><tr><td>31055-31056</td><td>Analog input #28 (Float)</td><td>Read</td></tr><tr><td>31057-31058</td><td>Analog input #29 (Float)</td><td>Read</td></tr><tr><td>31059-31060</td><td>Analog input #30 (Float)</td><td>Read</td></tr><tr><td>31061-31062</td><td>Analog input #31 (Float)</td><td>Read</td></tr><tr><td>31063-31064</td><td>Analog input #32 (Float)</td><td>Read</td></tr><tr><td>31065-31066</td><td>Analog input #33 (Float)</td><td>Read</td></tr><tr><td>31067-31068</td><td>Analog input #34 (Float)</td><td>Read</td></tr><tr><td>31069-31070</td><td>Analog input #35 (Float)</td><td>Read</td></tr><tr><td>31071-31072</td><td>Analog input #36 (Float)</td><td>Read</td></tr><tr><td>31073-31074</td><td>Analog input #37 (Float)</td><td>Read</td></tr><tr><td>31075-31076</td><td>Analog input #38 (Float)</td><td>Read</td></tr><tr><td>31077-31078</td><td>Analog input #39 (Float)</td><td>Read</td></tr><tr><td>31079-31080</td><td>Analog input #40 (Float)</td><td>Read</td></tr><tr><td><strong><em>Address</em></strong></td><td><strong><em>Description</em></strong></td><td><strong><em>Attribute</em></strong></td></tr><tr><td>40001</td><td>Analog input #1 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40002</td><td>Analog input #2 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40003</td><td>Analog input #3 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40004</td><td>Analog input #4 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40005</td><td>Analog input #5 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40006</td><td>Analog input #6 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40007</td><td>Analog input #7 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40008</td><td>Analog input #8 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40009</td><td>Analog input #9 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40010</td><td>Analog input #10 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40011</td><td>Analog input #11 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40012</td><td>Analog input #12 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40013</td><td>Analog input #13 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40014</td><td>Analog input #14 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40015</td><td>Analog input #15 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40016</td><td>Analog input #16 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40017</td><td>Analog input #17 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40018</td><td>Analog input #18 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40019</td><td>Analog input #19 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40020</td><td>Analog input #20 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40021</td><td>Analog input #21 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40022</td><td>Analog input #22 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40023</td><td>Analog input #23 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40024</td><td>Analog input #24 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40025</td><td>Analog input #25 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40026</td><td>Analog input #26 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40027</td><td>Analog input #27 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40028</td><td>Analog input #28 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40029</td><td>Analog input #29 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40030</td><td>Analog input #30 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40031</td><td>Analog input #31 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40032</td><td>Analog input #32 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40033</td><td>Analog input #33 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40034</td><td>Analog input #34 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40035</td><td>Analog input #35 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40036</td><td>Analog input #36 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40037</td><td>Analog input #37 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40038</td><td>Analog input #38 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40039</td><td>Analog input #39 voltage range (x10)</td><td>Read/Write</td></tr><tr><td>40040</td><td>Analog input #40 voltage range (x10)</td><td>Read/Write</td></tr><tr><td></td><td></td><td></td></tr><tr><td><strong><em>NEURO DIGITAL INPUTS</em></strong></td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td><strong><em>Address</em></strong></td><td><strong><em>Description</em></strong></td><td><strong><em>Attribute</em></strong></td></tr><tr><td>10001</td><td>Digital input #1 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10002</td><td>Digital input #2 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10003</td><td>Digital input #3 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10004</td><td>Digital input #4 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10005</td><td>Digital input #5 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10006</td><td>Digital input #6 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10007</td><td>Digital input #7 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10008</td><td>Digital input #8 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10009</td><td>Digital input #9 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10010</td><td>Digital input #10 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10011</td><td>Digital input #11 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10012</td><td>Digital input #12 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10013</td><td>Digital input #13 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10014</td><td>Digital input #14 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10015</td><td>Digital input #15 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10016</td><td>Digital input #16 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10017</td><td>Digital input #17 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10018</td><td>Digital input #18 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10019</td><td>Digital input #19 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10020</td><td>Digital input #20 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10021</td><td>Digital input #21 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10022</td><td>Digital input #22 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10023</td><td>Digital input #23 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10024</td><td>Digital input #24 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10025</td><td>Digital input #25 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10026</td><td>Digital input #26 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10027</td><td>Digital input #27 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10028</td><td>Digital input #28 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10029</td><td>Digital input #29 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10030</td><td>Digital input #30 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10031</td><td>Digital input #31 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10032</td><td>Digital input #32 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10033</td><td>Digital input #33 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10034</td><td>Digital input #34 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10035</td><td>Digital input #35 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10036</td><td>Digital input #36 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10037</td><td>Digital input #37 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10038</td><td>Digital input #38 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10039</td><td>Digital input #39 (1=High, 0=Low)</td><td>Read</td></tr><tr><td>10040</td><td>Digital input #40 (1=High, 0=Low)</td><td>Read</td></tr><tr><td></td><td></td><td></td></tr><tr><td><strong><em>NEURO RELAY OUTPUTS</em></strong></td><td>&nbsp;</td><td>&nbsp;</td></tr><tr><td><strong><em>Address</em></strong></td><td><strong><em>Description</em></strong></td><td><strong><em>Attribute</em></strong></td></tr><tr><td>00001</td><td>Relay #1 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00002</td><td>Relay #2 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00003</td><td>Relay #3 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00004</td><td>Relay #4 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00005</td><td>Relay #5 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00006</td><td>Relay #6 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00007</td><td>Relay #7 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00008</td><td>Relay #8 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00009</td><td>Relay #9 (1=Energized, 0=Released)</td><td>Read/Write</td></tr><tr><td>00010</td><td>Relay #10 (1=Energized, 0=Released)</td><td>Read/Write</td></tr></tbody></table></figure><p>The post <a href="https://dex.davicom.com/kb/axon-neuro-as-a-modbus-unit/">AXON/NEURO as a Modbus Unit</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dex.davicom.com/kb/axon-neuro-as-a-modbus-unit/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>AXON/NEURO Menus and General Navigation Guidelines</title>
		<link>https://dex.davicom.com/kb/axon-neuro-menus-and-general-navigation-guidelines/</link>
					<comments>https://dex.davicom.com/kb/axon-neuro-menus-and-general-navigation-guidelines/#respond</comments>
		
		<dc:creator><![CDATA[Julia Ahern]]></dc:creator>
		<pubDate>Fri, 26 Jul 2024 18:27:43 +0000</pubDate>
				<guid isPermaLink="false">https://dex.davicom.com/?post_type=kb&#038;p=6453</guid>

					<description><![CDATA[<p>Menus Home page—shows I/O readings and gives access to the configuration menu. Clicking on the hamburger menu at the upper left will open up the main<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://dex.davicom.com/kb/axon-neuro-menus-and-general-navigation-guidelines/">AXON/NEURO Menus and General Navigation Guidelines</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="wp-block-heading">Menus</h2><p>Home page—shows I/O readings and gives access to the configuration menu.</p><div class="wp-block-image"><figure class="aligncenter size-full"><img loading="lazy" decoding="async" width="687" height="814" src="https://dex.davicom.com/wp-content/uploads/2024/07/image016.png" alt="" class="wp-image-6379" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image016.png 687w, https://dex.davicom.com/wp-content/uploads/2024/07/image016-253x300.png 253w, https://dex.davicom.com/wp-content/uploads/2024/07/image016-123x146.png 123w, https://dex.davicom.com/wp-content/uploads/2024/07/image016-42x50.png 42w, https://dex.davicom.com/wp-content/uploads/2024/07/image016-63x75.png 63w, https://dex.davicom.com/wp-content/uploads/2024/07/image016-219x260.png 219w, https://dex.davicom.com/wp-content/uploads/2024/07/image016-600x711.png 600w" sizes="auto, (max-width:767px) 480px, 687px" /></figure></div><p></p><p>Clicking on the hamburger menu at the upper left will open up the main configuration drop-down menu.</p><figure class="wp-block-image"><img loading="lazy" decoding="async" width="412" height="243" src="https://dex.davicom.com/wp-content/uploads/2024/07/image017.png" alt="" class="wp-image-6380" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image017.png 412w, https://dex.davicom.com/wp-content/uploads/2024/07/image017-300x177.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/image017-248x146.png 248w, https://dex.davicom.com/wp-content/uploads/2024/07/image017-50x29.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/image017-127x75.png 127w, https://dex.davicom.com/wp-content/uploads/2024/07/image017-380x224.png 380w" sizes="auto, (max-width:767px) 412px, 412px" /></figure><p>Main Configuration drop-down menu:</p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="225" height="694" src="https://dex.davicom.com/wp-content/uploads/2024/07/image018.png" alt="" class="wp-image-6381" style="width:181px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image018.png 225w, https://dex.davicom.com/wp-content/uploads/2024/07/image018-97x300.png 97w, https://dex.davicom.com/wp-content/uploads/2024/07/image018-47x146.png 47w, https://dex.davicom.com/wp-content/uploads/2024/07/image018-16x50.png 16w, https://dex.davicom.com/wp-content/uploads/2024/07/image018-24x75.png 24w, https://dex.davicom.com/wp-content/uploads/2024/07/image018-84x260.png 84w" sizes="auto, (max-width:767px) 225px, 225px" /></figure></div><p></p><p>General Menu structure:</p><figure class="wp-block-table"><table><tbody><tr><td>HOME</td><td colspan="3"><em>Returns to Home page</em><em> </em><em>&nbsp;</em></td></tr><tr><td rowspan="4">LOGS</td><td>SYSTEM LOG</td><td colspan="2"><em>Displays complete System Log</em></td></tr><tr><td>DATA LOG</td><td colspan="2"><em>Displays individual Data Logs</em></td></tr><tr><td>DATA LOG CONFIG</td><td colspan="2"><em>Configuration of Data Log settings&nbsp;</em></td></tr><tr><td>TRANSFER PARAMETERS</td><td colspan="2"><em>Configuration of Log transfer parameters (email, frequency…)&nbsp;</em></td></tr><tr><td>JOBS</td><td colspan="3">&nbsp;<em>Configuration of up to 4 JOBS (also known as State Machines)</em></td></tr><tr><td rowspan="8">INPUTS</td><td>ACTIVITY MONITORING</td><td colspan="2"><em>Used to monitor and/or cumulate activity duration of up to 8 Inputs or IDs</em></td></tr><tr><td>ANALOGS (AXON-8A only)</td><td colspan="2"><em>Configures settings for 8 Analog Inputs (thresholds, conditions…)</em></td></tr><tr><td>COUNTERS</td><td colspan="2"><em>Configures settings for 8 counters (Up, Down, Reset, Initial Value…)</em></td></tr><tr><td>DIGITALS (AXON-8D only)</td><td colspan="2"><em>Configures settings for 8 Digital Inputs (active High, active Low…)</em></td></tr><tr><td>FLAGS</td><td colspan="2"><em>Configures alarm settings for 5 System Flags</em></td></tr><tr><td>MATH FUNCTIONS</td><td colspan="2"><em>Configuration of 8 Math functions (+,-,*, log, VSWR, Average…)</em></td></tr><tr><td>PING</td><td colspan="2"><em>Configuration of Network Ping (address, delay, period…)</em></td></tr><tr><td>SCHEDULERS</td><td colspan="2"><em>Configuration of 8 schedulers (hourly, daily, weekly …)</em></td></tr><tr><td rowspan="3">OUTPUTS</td><td>Axon/Neuro Commands</td><td colspan="2"><em>Configuration of Commands between AXON units</em></td></tr><tr><td>Davicom Cortex/DV200 Commands</td><td colspan="2"><em>Configuration of Commands to Davicom CORTEX/DV200 units&nbsp;</em></td></tr><tr><td>RELAYS (AXON-5R only)</td><td colspan="2"><em>Configuration of Relay settings (mode, pulse width, colours…)</em></td></tr><tr><td rowspan="19">SYSTEM</td><td>ABOUT</td><td colspan="2"><em>Displays unit serial number, firmware version…</em></td></tr><tr><td rowspan="3">ADMINISTRATION</td><td>GENERAL</td><td><em>Reboot, factory reset, firmware update…</em></td></tr><tr><td>CONFIGURATION TRANSFER</td><td><em>Import or export (save) unit configuration</em></td></tr><tr><td>PRODUCTION</td><td><em>Reserved for production &amp; tests</em></td></tr><tr><td>ALARM CALL LISTS</td><td colspan="2"><em>Configuration of alarm call delays, modes, mute times, targets …&nbsp;</em></td></tr><tr><td rowspan="4">DATE, TIME &amp; LOCATION</td><td>MANUAL</td><td><em>Manual setting of date and time&nbsp;</em></td></tr><tr><td>NTP SYNC</td><td><em>NTP Server address, sync time…</em></td></tr><tr><td>DAYLIGHT SAVING TIME</td><td><em>Automatic DST start/end dates …</em></td></tr><tr><td>LOCATION</td><td><em>Latitude &amp; Longitude settings for Sunrise/Sunset calculations &amp; map displays</em></td></tr><tr><td rowspan="6">IP PARAMETERS</td><td>GENERAL</td><td><em>General IP settings</em></td></tr><tr><td>E-MAIL</td><td><em>E-mail server, port &amp; authentication settings</em></td></tr><tr><td>WEB</td><td><em>Internal Web server settings</em></td></tr><tr><td>SNMP</td><td><em>SNMP Agent settings (V1, V2c, V3 …)</em></td></tr><tr><td>AXON/NEURO COMMAND SERVER</td><td><em>AXON/NEURO Command Server security &amp; port settings&nbsp;</em></td></tr><tr><td>SSL CERTIFICATE</td><td><em>SSL Certificate Encryption and settings</em></td></tr><tr><td>SITE ID</td><td colspan="2"><em>Site ID &amp; Name &nbsp;</em></td></tr><tr><td rowspan="3">USERS</td><td>SUPERVISOR</td><td><em>Set SUPERVISOR Role Username &amp; Password</em><em>Must be configured on initial log-in.</em></td></tr><tr><td>OPERATOR</td><td><em>Set OPERATOR Role Username &amp; Password</em></td></tr><tr><td>VIEWER</td><td><em>Set VIEWER Role Username &amp; Password.</em></td></tr></tbody></table></figure><h2 class="wp-block-heading">Button identification and functions </h2><p>When in selected configuration windows, the following buttons will generally appear at the bottom of the window.</p><figure class="wp-block-table"><table><tbody><tr><td><br><img loading="lazy" decoding="async" width="72" height="52" class="wp-image-6382" style="width: 72px;" src="https://dex.davicom.com/wp-content/uploads/2024/07/image019.png" alt="" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image019.png 72w, https://dex.davicom.com/wp-content/uploads/2024/07/image019-50x36.png 50w" sizes="auto, (max-width:767px) 72px, 72px" /></td><td>Delete</td></tr><tr><td><br><img loading="lazy" decoding="async" width="71" height="47" class="wp-image-6383" style="width: 71px;" src="https://dex.davicom.com/wp-content/uploads/2024/07/image020.png" alt="" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image020.png 71w, https://dex.davicom.com/wp-content/uploads/2024/07/image020-50x33.png 50w" sizes="auto, (max-width:767px) 71px, 71px" /></td><td>Refreshes the web page (note that any changes made to the page will be lost if not saved first)&nbsp;</td></tr><tr><td><br><img loading="lazy" decoding="async" width="72" height="54" class="wp-image-6384" style="width: 72px;" src="https://dex.davicom.com/wp-content/uploads/2024/07/image021.png" alt="" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image021.png 72w, https://dex.davicom.com/wp-content/uploads/2024/07/image021-50x38.png 50w" sizes="auto, (max-width:767px) 72px, 72px" /></td><td>Apply Changes (Save )</td></tr><tr><td><br><img loading="lazy" decoding="async" width="70" height="51" class="wp-image-6385" style="width: 70px;" src="https://dex.davicom.com/wp-content/uploads/2024/07/image022.png" alt="" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image022.png 70w, https://dex.davicom.com/wp-content/uploads/2024/07/image022-50x36.png 50w" sizes="auto, (max-width:767px) 70px, 70px" /></td><td>The “*” symbol on the Save button shows that changes have been made to the page/view and that a Save should be performed</td></tr><tr><td><br><img loading="lazy" decoding="async" width="73" height="50" class="wp-image-6386" style="width: 73px;" src="https://dex.davicom.com/wp-content/uploads/2024/07/image023.png" alt="" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image023.png 73w, https://dex.davicom.com/wp-content/uploads/2024/07/image023-50x34.png 50w" sizes="auto, (max-width:767px) 73px, 73px" /></td><td>Return to Home page&nbsp;</td></tr></tbody></table></figure><p>The post <a href="https://dex.davicom.com/kb/axon-neuro-menus-and-general-navigation-guidelines/">AXON/NEURO Menus and General Navigation Guidelines</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dex.davicom.com/kb/axon-neuro-menus-and-general-navigation-guidelines/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>AXON/NEURO Specifications</title>
		<link>https://dex.davicom.com/kb/axon-neuro-specifications/</link>
					<comments>https://dex.davicom.com/kb/axon-neuro-specifications/#respond</comments>
		
		<dc:creator><![CDATA[Julia Ahern]]></dc:creator>
		<pubDate>Tue, 30 Jul 2024 15:46:02 +0000</pubDate>
				<guid isPermaLink="false">https://dex.davicom.com/?post_type=kb&#038;p=6512</guid>

					<description><![CDATA[<p>Metering (Analog) Inputs AXON-8A: 8, bipolar, differential,&#160;12 bit resolution, ±0.5. ±2.5. ±5, ±10, ±20, +40 or -40 V, 1 MΩ, 4-20 mA mode. Status (Digital) Inputs<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://dex.davicom.com/kb/axon-neuro-specifications/">AXON/NEURO Specifications</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></description>
										<content:encoded><![CDATA[<figure class="wp-block-table"><table><tbody><tr><td>Metering (Analog) Inputs AXON-8A:</td><td>8, bipolar, differential,&nbsp;12 bit resolution, ±0.5. ±2.5. ±5, ±10, ±20, +40 or -40 V, 1 MΩ, 4-20 mA mode.</td></tr><tr><td>Status (Digital) Inputs AXON-8D:</td><td>8 with separate internal or external grounds. Max input : ±65 V, 10 kΩ.</td></tr><tr><td>Outputs (Command Relays) AXON-5R:</td><td>5, Form C. 70 VAC @ 0.4 A, 30 Vdc @ 2A&nbsp;</td></tr><tr><td>Alarms:</td><td>Email, SNMP TRAP/INFORM</td></tr><tr><td>Alarm Call Lists:</td><td>5&nbsp;</td></tr><tr><td>Protocols (OSI Layers)&nbsp;</td><td>1&nbsp;: 10BASE-T, 100BASE-T&nbsp;2&nbsp;: Ethernet, MAC&nbsp;3&nbsp;: ARP, ICMP, IPv4&nbsp;4&nbsp;: TCP, UDP&nbsp;5&nbsp;: Raw Socket&nbsp;6&nbsp;: DTLS, TLS 1.2, TLS 1.3, SSL&nbsp;7&nbsp;: CoAP over DTLS, DNS, HTTP, HTTPS, Modbus/TCP,&nbsp;SMTP over SSL/TLS, SNMP Agent v1/v2c/v3, SNTP&nbsp;</td></tr><tr><td>Jobs:</td><td>4&nbsp;</td></tr><tr><td>Event Schedulers:</td><td>8&nbsp;</td></tr><tr><td>Math Functions:</td><td>8&nbsp;</td></tr><tr><td>Remote Commands (Outbound):</td><td>8&nbsp;</td></tr><tr><td>Counters:</td><td>8&nbsp;</td></tr><tr><td>SNMP Agent:</td><td>Yes (v1/V2c/V3)&nbsp;</td></tr><tr><td>Modbus Slave Mode:</td><td>Yes&nbsp;</td></tr><tr><td>Ethernet Ports:</td><td>1&nbsp;</td></tr><tr><td>Power Supply:</td><td>5-30 Vdc. Typ 110 mA @ 12 Vdc. Max 190 mA with 5 relays energized @ 12 Vdc.&nbsp;</td></tr><tr><td>Operating Temperature:</td><td>-40° to +70°C&nbsp;</td></tr><tr><td>Dimensions:</td><td>3” x 5 3/8” x 1 1/4”&nbsp;</td></tr><tr><td>Mounting:</td><td>Direct wall mount or DIN rail&nbsp;</td></tr><tr><td>Weight:</td><td>1 lbs</td></tr></tbody></table></figure><p>The post <a href="https://dex.davicom.com/kb/axon-neuro-specifications/">AXON/NEURO Specifications</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dex.davicom.com/kb/axon-neuro-specifications/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Davicom Input/Output/Flag/System Identifier Names</title>
		<link>https://dex.davicom.com/kb/davicom-input-output-flag-system-identifier-names/</link>
					<comments>https://dex.davicom.com/kb/davicom-input-output-flag-system-identifier-names/#respond</comments>
		
		<dc:creator><![CDATA[Julia Ahern]]></dc:creator>
		<pubDate>Fri, 26 Jul 2024 19:16:54 +0000</pubDate>
				<guid isPermaLink="false">https://dex.davicom.com/?post_type=kb&#038;p=6468</guid>

					<description><![CDATA[<p>Note: n=device number x to xxxx = ID number (between 1 and 1024) Type ID Description Input nAxx Analog Inputs System 1ACLxx Alarm Call List Flag<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://dex.davicom.com/kb/davicom-input-output-flag-system-identifier-names/">Davicom Input/Output/Flag/System Identifier Names</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-2 wp-block-group-is-layout-flex"><p><strong>Note: </strong></p>

<p>n=device number</p>

<p>x to xxxx = ID number (between 1 and 1024)</p></div><figure class="wp-block-table is-style-stripes"><table><tbody><tr><td><strong>Type</strong></td><td><strong>ID</strong></td><td><strong><mark style="background-color:rgba(0, 0, 0, 0)" class="has-inline-color has-black-color">Description</mark></strong></td></tr><tr><td>Input</td><td>nAxx</td><td>Analog Inputs</td></tr><tr><td>System</td><td>1ACLxx</td><td>Alarm Call List</td></tr><tr><td>Flag</td><td>1B1</td><td>RAM Battery</td></tr><tr><td>Flag</td><td>1B2</td><td>Battery Discharge Test</td></tr><tr><td>Input</td><td>1Cxxx</td><td>Command Flags</td></tr><tr><td>System</td><td>1CLx</td><td>Custom Log</td></tr><tr><td>Input</td><td>1CTxx</td><td>Counters</td></tr><tr><td>Input</td><td>nDxx</td><td>Digital Inputs</td></tr><tr><td>Device</td><td>xDAx</td><td>DADS</td></tr><tr><td>Flag</td><td>1DST</td><td>Daylight Savings Time</td></tr><tr><td>Flag</td><td>1E01</td><td>Alarm Calls Disabled: Active when Alarm-calls disabled</td></tr><tr><td>Input</td><td>1Fxx</td><td>Math Functions</td></tr><tr><td>Device</td><td>1FMx</td><td>FM Broadcast Monitor</td></tr><tr><td>Input</td><td>1Gxxx</td><td>General Activity Monitoring</td></tr><tr><td>Input</td><td>1Hxxx</td><td>Timers</td></tr><tr><td>Flag</td><td>1J1</td><td>Processor Board Temperature</td></tr><tr><td>Flag</td><td>1J2</td><td>CPU Temperature</td></tr><tr><td>Flag</td><td>1L1</td><td>Phone Line Dial Tone: Active if no dial-tone</td></tr><tr><td>Device</td><td>1LD</td><td>Lightning Detection Device</td></tr><tr><td>Device</td><td>nLD1</td><td>Lightning Detection Distance</td></tr><tr><td>Device</td><td>nLD2</td><td>Lightning Detector Noise Level</td></tr><tr><td>Device</td><td>nLD3</td><td>Lightning Detector Disturber detected</td></tr><tr><td>Device</td><td>nLD4</td><td>Lightning Detected</td></tr><tr><td>Device</td><td>nMAxx</td><td>Modbus Analog Input</td></tr><tr><td>Device</td><td>nMDxx</td><td>Modbus Digital Input</td></tr><tr><td>Device</td><td>nMRxx</td><td>Modbus Relay</td></tr><tr><td>Device</td><td>nMTxx</td><td>Modbus Activity Monitor</td></tr><tr><td>Input</td><td>1Nxx</td><td>Network Ping: Active if no reply to ping</td></tr><tr><td>Output</td><td>1Oxxx</td><td>Virtual Relay Output</td></tr><tr><td>Flag</td><td>1P1</td><td>AC Power Fail: Active if no AC</td></tr><tr><td>Flag</td><td>1P2</td><td>DC Power (12V Main)</td></tr><tr><td>Flag</td><td>1P3</td><td>Boot Flag</td></tr><tr><td>Flag</td><td>1P4</td><td>5V Aux</td></tr><tr><td>Flag</td><td>1P5</td><td>12V Aux</td></tr><tr><td>Flag</td><td>1P6</td><td>12V Relays</td></tr><tr><td>Flag</td><td>1P7</td><td>3.3V Main</td></tr><tr><td>Flag</td><td>1P8</td><td>Power-On Flag</td></tr><tr><td>Device</td><td>1PAxx</td><td>Pager</td></tr><tr><td>Output</td><td>1Rxx</td><td>Relay</td></tr><tr><td>Flag</td><td>1S1</td><td>Sunrise/Sunset: High at sunrise</td></tr><tr><td>Device</td><td>1SDxx</td><td>SNMP Device</td></tr><tr><td>Device</td><td>1SMPHx</td><td>Smartphone</td></tr><tr><td>Flag</td><td>1SA01</td><td>SNMP Alarm: Active if automatic check of SNMP Agent fails</td></tr><tr><td>Input</td><td>1SGxxxx</td><td>SNMP GET</td></tr><tr><td>Output</td><td>1SSxxxx</td><td>SNMP SET</td></tr><tr><td>Input</td><td>1STxxxx</td><td>SNMP TRAP</td></tr><tr><td>Input</td><td>1Txx</td><td>Digital Input Activity Monitoring</td></tr><tr><td>Device</td><td>1USBDx</td><td>USB Storage Device</td></tr><tr><td>Output</td><td>UUC</td><td>Unit to Unit Commands (used with C-Command Flags)</td></tr><tr><td>Input</td><td>1Vxxx</td><td>Virtual Logic Gate</td></tr><tr><td>Flag</td><td>1W1</td><td>Password Fail: Active after 5 failed login attempts</td></tr><tr><td>Flag</td><td>1Y1</td><td>Clock sync fail</td></tr></tbody></table></figure><div class="wp-block-buttons has-custom-font-size has-medium-font-size is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex"><div class="wp-block-button"><a class="wp-block-button__link wp-element-button" href="https://dex.davicom.com/wp-content/uploads/2024/07/Davicom-Identifiers.xlsx-Sheet1.pdf" target="_blank" rel="noreferrer noopener">Download PDF</a></div></div><p>The post <a href="https://dex.davicom.com/kb/davicom-input-output-flag-system-identifier-names/">Davicom Input/Output/Flag/System Identifier Names</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dex.davicom.com/kb/davicom-input-output-flag-system-identifier-names/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Home Page Explained (AXON/NEURO Series)</title>
		<link>https://dex.davicom.com/kb/home-page-explained-axon-neuro-series/</link>
					<comments>https://dex.davicom.com/kb/home-page-explained-axon-neuro-series/#respond</comments>
		
		<dc:creator><![CDATA[Julia Ahern]]></dc:creator>
		<pubDate>Fri, 26 Jul 2024 19:23:27 +0000</pubDate>
				<guid isPermaLink="false">https://dex.davicom.com/?post_type=kb&#038;p=6471</guid>

					<description><![CDATA[<p>The Home page shows the unit’s I/O readings as well as the status of all the calculations and monitoring it performs on a continuous basis. The<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://dex.davicom.com/kb/home-page-explained-axon-neuro-series/">Home Page Explained (AXON/NEURO Series)</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The Home page shows the unit’s I/O readings as well as the status of all the calculations and monitoring it performs on a continuous basis. The view presented below shows only a few elements from each section to help the image fit on this page. By default, absolutely every input and derived input is shown on the Home page. You can individually select, re-order, hide and filter them all.&nbsp;</p><p>The   <img loading="lazy" decoding="async" width="35" height="37" class="wp-image-6389" style="width: 35px;" src="https://dex.davicom.com/wp-content/uploads/2024/07/image026.png" alt="" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image026.png 55w, https://dex.davicom.com/wp-content/uploads/2024/07/image026-47x50.png 47w" sizes="auto, (max-width:767px) 35px, 35px" />   box at the very right of each element allows direct access to configure, and (depending on the type of input) to reset or control the element. You can also right-click on the element with the mouse.</p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="868" height="827" src="https://dex.davicom.com/wp-content/uploads/2024/07/image027.png" alt="" class="wp-image-6390" style="width:747px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image027.png 868w, https://dex.davicom.com/wp-content/uploads/2024/07/image027-300x286.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/image027-768x732.png 768w, https://dex.davicom.com/wp-content/uploads/2024/07/image027-153x146.png 153w, https://dex.davicom.com/wp-content/uploads/2024/07/image027-50x48.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/image027-79x75.png 79w, https://dex.davicom.com/wp-content/uploads/2024/07/image027-273x260.png 273w, https://dex.davicom.com/wp-content/uploads/2024/07/image027-600x572.png 600w" sizes="auto, (max-width:767px) 480px, (max-width:868px) 100vw, 868px" /></figure></div><p>Filtered views are available through the <strong>Filter icon</strong>.</p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="813" height="590" src="https://dex.davicom.com/wp-content/uploads/2024/07/image028.png" alt="" class="wp-image-6391" style="width:675px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image028.png 813w, https://dex.davicom.com/wp-content/uploads/2024/07/image028-300x218.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/image028-768x557.png 768w, https://dex.davicom.com/wp-content/uploads/2024/07/image028-201x146.png 201w, https://dex.davicom.com/wp-content/uploads/2024/07/image028-50x36.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/image028-103x75.png 103w, https://dex.davicom.com/wp-content/uploads/2024/07/image028-358x260.png 358w, https://dex.davicom.com/wp-content/uploads/2024/07/image028-600x435.png 600w" sizes="auto, (max-width:767px) 480px, (max-width:813px) 100vw, 813px" /></figure></div><p>Each Home Page section is shown below (example shown is for AXON-8A). To see all of the points within each section, check the <strong>See all </strong>box at the upper left.&nbsp;</p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="757" height="670" src="https://dex.davicom.com/wp-content/uploads/2024/07/image029.png" alt="" class="wp-image-6392" style="width:565px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image029.png 757w, https://dex.davicom.com/wp-content/uploads/2024/07/image029-300x266.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/image029-165x146.png 165w, https://dex.davicom.com/wp-content/uploads/2024/07/image029-50x44.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/image029-85x75.png 85w, https://dex.davicom.com/wp-content/uploads/2024/07/image029-294x260.png 294w, https://dex.davicom.com/wp-content/uploads/2024/07/image029-600x531.png 600w" sizes="auto, (max-width:767px) 480px, 757px" /></figure></div><p>The post <a href="https://dex.davicom.com/kb/home-page-explained-axon-neuro-series/">Home Page Explained (AXON/NEURO Series)</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dex.davicom.com/kb/home-page-explained-axon-neuro-series/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>How to Measure VSWR with BPS RF Power Sensors and a Davicom RTU</title>
		<link>https://dex.davicom.com/kb/how-to-measure-vswr-with-bps-rf-power-sensors-and-a-davicom-cortex-unit/</link>
					<comments>https://dex.davicom.com/kb/how-to-measure-vswr-with-bps-rf-power-sensors-and-a-davicom-cortex-unit/#respond</comments>
		
		<dc:creator><![CDATA[Julia Ahern]]></dc:creator>
		<pubDate>Wed, 28 May 2025 17:50:34 +0000</pubDate>
				<guid isPermaLink="false">https://dex.davicom.com/?post_type=kb&#038;p=7232</guid>

					<description><![CDATA[<p>To measure VSWR (Voltage Standing Wave Ratio) using Davicom products such as the BPS1050 or BPS5095 RF Power Sensors, follow these steps: System Set Up 1-<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://dex.davicom.com/kb/how-to-measure-vswr-with-bps-rf-power-sensors-and-a-davicom-cortex-unit/">How to Measure VSWR with BPS RF Power Sensors and a Davicom RTU</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>To measure VSWR (Voltage Standing Wave Ratio) using Davicom products such as the BPS1050 or BPS5095 RF Power Sensors, follow these steps:</p><h2 class="wp-block-heading">System Set Up</h2><p>1- Connect the <strong>transmitter end</strong> of the BPS to your transmitter.</p><p>2- Attach the <strong>antenna end</strong> of the BPS to either an inline power meter (to verify power output) or directly to the load if the transmitter power is already known.</p><p>3- Connect the <strong>forward power</strong> and <strong>reflected power</strong> voltage terminals of the BPS to separate metering inputs on your Davicom RTU.</p><h2 class="wp-block-heading">Metering Inputs Configuration Using the Web Interface</h2><p>Configure the metering inputs for Forward Power and Reflected Power through the RTU&#8217;s web interface:</p><p>1- Open a web browser and connect to the Davicom RTU&#8217;s web interface using its IP address.</p><p>2- Navigate to <strong>Inputs &gt; Metering Inputs</strong>.</p><p>3- For each metering input:</p><ul class="wp-block-list"><li>Select the input connected to the Forward Power terminal of the BPS.</li>

<li>Configure the following parameters:<ul class="wp-block-list"><li><strong>Description:</strong> Forward Power</li>

<li><strong>Measurement Unit:</strong> Watts (or as applicable)</li>

<li><strong>Normal Value:</strong> Enter the typical forward power value for your setup.</li>

<li><strong>Calibration Coefficients:</strong> Input the specific coefficients (A, B, C) from the BPS documentation based on the operational frequency:<ul class="wp-block-list"><li><strong>BPS1050 at 170 MHz:</strong> A = 8.9053, B = 4.4987, C = 0</li>

<li><strong>BPS5095 at 870 MHz:</strong> A = 4.5311, B = 3.0904, C = 0</li></ul></li></ul></li>

<li>Repeat this process for the metering input connected to the Reflected Power terminal, adjusting the description accordingly.</li></ul><div class="wp-block-image"><figure class="aligncenter size-large is-resized"><img loading="lazy" decoding="async" width="1024" height="421" src="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133342-1024x421.png" alt="" class="wp-image-7233" style="width:557px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133342-1024x421.png 1024w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133342-300x123.png 300w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133342-768x315.png 768w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133342-150x62.png 150w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133342-380x156.png 380w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133342-480x197.png 480w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133342-800x329.png 800w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133342.png 1125w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure></div><div class="wp-block-image"><figure class="aligncenter size-large is-resized"><img loading="lazy" decoding="async" width="1024" height="574" src="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133407-1024x574.png" alt="" class="wp-image-7234" style="width:551px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133407-1024x574.png 1024w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133407-300x168.png 300w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133407-768x430.png 768w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133407-134x75.png 134w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133407-380x213.png 380w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133407-480x269.png 480w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133407-800x448.png 800w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133407.png 1123w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure></div><div class="wp-block-image"><figure class="aligncenter size-large is-resized"><img loading="lazy" decoding="async" width="1024" height="418" src="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133454-1024x418.png" alt="" class="wp-image-7235" style="width:551px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133454-1024x418.png 1024w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133454-300x122.png 300w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133454-768x313.png 768w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133454-150x61.png 150w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133454-380x155.png 380w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133454-480x196.png 480w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133454-800x327.png 800w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133454.png 1122w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure></div><div class="wp-block-image"><figure class="aligncenter size-large is-resized"><img loading="lazy" decoding="async" width="1024" height="571" src="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133524-1024x571.png" alt="" class="wp-image-7236" style="width:552px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133524-1024x571.png 1024w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133524-300x167.png 300w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133524-768x428.png 768w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133524-135x75.png 135w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133524-380x212.png 380w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133524-480x268.png 480w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133524-800x446.png 800w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-133524.png 1121w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure></div><h2 class="wp-block-heading">BPS Calibration</h2><p>Accurate calibration ensures the Davicom RTU&#8217;s forward power reading matches the actual transmitter output:</p><p>1- <strong>Use a Reference Meter:</strong> Set up an inline power meter between the BPS and the load to act as your reference.</p><p>2- <strong>Turn On the Transmitter:</strong> Power up the transmitter and stabilize its output.</p><p>3- <strong>Adjust the Calibration Trimmer:</strong></p><ul class="wp-block-list"><li>Locate the forward voltage calibration trimmer on the BPS sensor.</li>

<li>Using a small insulated screwdriver, gently adjust the trimmer while monitoring the forward power reading on the Davicom RTU.</li>

<li>Continue adjusting until the forward power reading displayed by the Davicom RTU matches the reference value shown on the inline power meter.</li></ul><h2 class="wp-block-heading">Automatic VSWR Calculation Configuration</h2><p>Once the metering inputs are calibrated, you can set up automatic VSWR calculation:</p><p>1- Navigate to <strong>Inputs &gt; Math Functions</strong> in the RTU&#8217;s web interface.</p><p>2- Choose an available math function slot.</p><p>3- In the <strong>Operator</strong> dropdown menu, select the <strong>SWR</strong> function.</p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="547" height="58" src="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134219.png" alt="" class="wp-image-7237" style="width:434px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134219.png 547w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134219-300x32.png 300w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134219-150x16.png 150w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134219-380x40.png 380w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134219-480x51.png 480w" sizes="auto, (max-width:767px) 480px, 547px" /></figure></div><p>4- In the fields provided for the SWR operator:</p><ul class="wp-block-list"><li><strong>Field A (Reflected Power):</strong> Enter the ID for the metering input connected to the reflected power terminal of the BPS.<br>For example, if Reflected Power is connected to Metering Input 8, the ID will typically be 1A8.</li>

<li><strong>Field B (Forward Power):</strong> Enter the ID for the metering input connected to the forward power terminal of the BPS.<br>For example, if Forward Power is connected to Metering Input 7, the ID will typically be 1A7.</li></ul><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="540" height="335" src="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134302.png" alt="" class="wp-image-7238" style="width:485px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134302.png 540w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134302-300x186.png 300w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134302-121x75.png 121w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134302-380x236.png 380w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134302-480x298.png 480w" sizes="auto, (max-width:767px) 480px, 540px" /></figure></div><p>5- Assign a description to the math function, such as &#8220;VSWR Calculation.&#8221;</p><div class="wp-block-image"><figure class="aligncenter size-large is-resized"><img loading="lazy" decoding="async" width="1024" height="422" src="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134333-1024x422.png" alt="" class="wp-image-7239" style="width:655px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134333-1024x422.png 1024w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134333-300x124.png 300w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134333-768x316.png 768w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134333-150x62.png 150w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134333-380x156.png 380w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134333-480x198.png 480w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134333-800x329.png 800w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134333.png 1127w" sizes="auto, (max-width:767px) 480px, (max-width:1024px) 100vw, 1024px" /></figure></div><p>6- Save the settings to activate the VSWR calculation.</p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="141" height="77" src="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-095613.png" alt="" class="wp-image-7219" style="width:115px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-095613.png 141w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-095613-137x75.png 137w" sizes="auto, (max-width:767px) 141px, 141px" /></figure></div><h2 class="wp-block-heading">Displaying VSWR Reading</h2><p>1- Navigate to the monitoring panel in the web interface.</p><p>2- Add the configured math function to a dashboard or display panel for real-time VSWR monitoring.</p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="474" height="381" src="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134410.png" alt="" class="wp-image-7240" style="width:362px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134410.png 474w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134410-300x241.png 300w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134410-93x75.png 93w, https://dex.davicom.com/wp-content/uploads/2025/05/Screenshot-2025-05-28-134410-323x260.png 323w" sizes="auto, (max-width:767px) 474px, 474px" /></figure></div><p>The post <a href="https://dex.davicom.com/kb/how-to-measure-vswr-with-bps-rf-power-sensors-and-a-davicom-cortex-unit/">How to Measure VSWR with BPS RF Power Sensors and a Davicom RTU</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dex.davicom.com/kb/how-to-measure-vswr-with-bps-rf-power-sensors-and-a-davicom-cortex-unit/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Initial Log-in and Network Setup (AXON/NEURO Series)</title>
		<link>https://dex.davicom.com/kb/initial-log-in-and-network-setup-axon-neuro-series/</link>
					<comments>https://dex.davicom.com/kb/initial-log-in-and-network-setup-axon-neuro-series/#respond</comments>
		
		<dc:creator><![CDATA[Julia Ahern]]></dc:creator>
		<pubDate>Fri, 26 Jul 2024 19:07:03 +0000</pubDate>
				<guid isPermaLink="false">https://dex.davicom.com/?post_type=kb&#038;p=6457</guid>

					<description><![CDATA[<p>Default IP address (192.168.1.210) The AXON/NEURO’s factory default IP address is 192.168.1.210. For the next steps, you will need to temporarily set your computer’s IP address<span class="excerpt-hellip"> […]</span></p>
<p>The post <a href="https://dex.davicom.com/kb/initial-log-in-and-network-setup-axon-neuro-series/">Initial Log-in and Network Setup (AXON/NEURO Series)</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2 class="wp-block-heading">Default IP address (192.168.1.210)</h2><p>The AXON/NEURO’s factory default IP address is 192.168.1.210.</p><p>For the next steps, you will need to temporarily set your computer’s IP address within this range or create an Alias in your computer’s Network settings. For example, you can use 192.168.1.211.</p><h2 class="wp-block-heading">Mandatory initial login credential change</h2><p>The state of California has enacted regulation SB-327 that dictates that all IoT devices that are sold or offered in the state of California must adhere to specific regulations in regards to passwords configured on the device. All passwords are required to either be unique or prompt for a password change before the user has access to it.</p><p>Upon first log-in, AXON/NEURO units require that a Supervisor User enter their own password. Default, factory-set passwords are no longer allowed.&nbsp;</p><p>NOTE: This is also the point where you can select whether the AXON/NEURO will be configured as a Standalone unit for Web &amp; SNMP or if it will be used as a MODBUS slave unit.</p><p>This mode can be changed later, from the <strong>Administration/General</strong> menu, without doing a factory reset.</p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="790" height="810" src="https://dex.davicom.com/wp-content/uploads/2024/07/image024.png" alt="" class="wp-image-6387" style="width:534px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image024.png 790w, https://dex.davicom.com/wp-content/uploads/2024/07/image024-293x300.png 293w, https://dex.davicom.com/wp-content/uploads/2024/07/image024-768x787.png 768w, https://dex.davicom.com/wp-content/uploads/2024/07/image024-142x146.png 142w, https://dex.davicom.com/wp-content/uploads/2024/07/image024-50x50.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/image024-73x75.png 73w, https://dex.davicom.com/wp-content/uploads/2024/07/image024-254x260.png 254w, https://dex.davicom.com/wp-content/uploads/2024/07/image024-600x615.png 600w" sizes="auto, (max-width:767px) 480px, (max-width:790px) 100vw, 790px" /></figure></div><p>After this initial step, the first Login process can take up to 30 seconds while the system configures its setup and web page views.</p><h2 class="wp-block-heading">Network setup</h2><p>Once you have set the username and passwords, you will be able to access the setup menu. From the Home Page, click on the hamburger menu at the upper left.</p><figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="412" height="243" src="https://dex.davicom.com/wp-content/uploads/2024/07/image017.png" alt="" class="wp-image-6380" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image017.png 412w, https://dex.davicom.com/wp-content/uploads/2024/07/image017-300x177.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/image017-248x146.png 248w, https://dex.davicom.com/wp-content/uploads/2024/07/image017-50x29.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/image017-127x75.png 127w, https://dex.davicom.com/wp-content/uploads/2024/07/image017-380x224.png 380w" sizes="auto, (max-width:767px) 412px, 412px" /></figure><p>The following drop-down menu will appear.</p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="225" height="694" src="https://dex.davicom.com/wp-content/uploads/2024/07/image018.png" alt="" class="wp-image-6381" style="width:149px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/image018.png 225w, https://dex.davicom.com/wp-content/uploads/2024/07/image018-97x300.png 97w, https://dex.davicom.com/wp-content/uploads/2024/07/image018-47x146.png 47w, https://dex.davicom.com/wp-content/uploads/2024/07/image018-16x50.png 16w, https://dex.davicom.com/wp-content/uploads/2024/07/image018-24x75.png 24w, https://dex.davicom.com/wp-content/uploads/2024/07/image018-84x260.png 84w" sizes="auto, (max-width:767px) 225px, 225px" /></figure></div><p>Select <strong>IP Parameters</strong> and then the <strong>General Tab</strong></p><h3 class="wp-block-heading"> General IP settings </h3><p>Set the <strong>IP Address</strong>, <strong>Netmask</strong>, <strong>Gateway</strong> and <strong>DNS</strong> for your unit.</p><p><em>NOTE: The numbers entered in the fields below are only used as examples. Do not enter the numbers as you see them below, you must set the information according to your own device and network setup.&nbsp;</em></p><figure class="wp-block-gallery aligncenter has-nested-images columns-default is-cropped wp-block-gallery-4 is-layout-flex wp-block-gallery-is-layout-flex"><figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="988" height="474" data-id="6460" src="https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150114.png" alt="" class="wp-image-6460" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150114.png 988w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150114-300x144.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150114-768x368.png 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150114-260x125.png 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150114-50x24.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150114-150x72.png 150w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150114-380x182.png 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150114-600x288.png 600w" sizes="auto, (max-width:767px) 480px, (max-width:988px) 100vw, 988px" /></figure>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="986" height="473" data-id="6461" src="https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150151.png" alt="" class="wp-image-6461" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150151.png 986w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150151-300x144.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150151-768x368.png 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150151-260x125.png 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150151-50x24.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150151-150x72.png 150w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150151-380x182.png 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150151-600x288.png 600w" sizes="auto, (max-width:767px) 480px, (max-width:986px) 100vw, 986px" /></figure></figure><p>It is very important to set a gateway, otherwise, the unit may not communicate successfully with the outside network.&nbsp;</p><figure class="wp-block-gallery aligncenter has-nested-images columns-default is-cropped wp-block-gallery-5 is-layout-flex wp-block-gallery-is-layout-flex"><figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="987" height="473" data-id="6465" src="https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150458.png" alt="" class="wp-image-6465" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150458.png 987w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150458-300x144.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150458-768x368.png 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150458-260x125.png 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150458-50x24.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150458-150x72.png 150w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150458-380x182.png 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150458-600x288.png 600w" sizes="auto, (max-width:767px) 480px, (max-width:987px) 100vw, 987px" /></figure>

<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="987" height="473" data-id="6464" src="https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150435.png" alt="" class="wp-image-6464" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150435.png 987w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150435-300x144.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150435-768x368.png 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150435-260x125.png 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150435-50x24.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150435-150x72.png 150w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150435-380x182.png 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150435-600x288.png 600w" sizes="auto, (max-width:767px) 480px, (max-width:987px) 100vw, 987px" /></figure></figure><p><strong>Save</strong> the IP settings. </p><div class="wp-block-image"><figure class="aligncenter size-full is-resized"><img loading="lazy" decoding="async" width="989" height="474" src="https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150613.png" alt="" class="wp-image-6466" style="width:501px;height:auto" srcset="https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150613.png 989w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150613-300x144.png 300w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150613-768x368.png 768w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150613-260x125.png 260w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150613-50x24.png 50w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150613-150x72.png 150w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150613-380x182.png 380w, https://dex.davicom.com/wp-content/uploads/2024/07/Screenshot-2024-07-26-150613-600x288.png 600w" sizes="auto, (max-width:767px) 480px, (max-width:989px) 100vw, 989px" /></figure></div><p>The post <a href="https://dex.davicom.com/kb/initial-log-in-and-network-setup-axon-neuro-series/">Initial Log-in and Network Setup (AXON/NEURO Series)</a> appeared first on <a href="https://dex.davicom.com">Davicom Exchange Support Portal (DEX)</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://dex.davicom.com/kb/initial-log-in-and-network-setup-axon-neuro-series/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>